
Levasseur Merril Retractor Fiber Optic
$139
SKU:RM-HER-475-1-1
$179USD
Henner Endaural Retractor is used to retract endaural incision margins and the external auditory canal during otologic ear surgery. Its curved blades and mechanical lock maintain hands-free exposure, while an ergonomically contoured handle frame provides a firm grip. Supplied non-sterile, it is fully autoclavable.
Henner Endaural Retractor is a self-retaining otologic instrument used in ear surgery to retract endaural incision margins and the external auditory canal. It provides hands-free exposure of the tympanic membrane and middle ear structures during endaural procedures.
Anatomically curved, smooth blades spread meatal incisions without obstructing the microscopic line of sight or delicate micro-instruments. A mechanical locking system maintains steady, continuous spread. The ergonomically contoured handle frame provides a firm grip. It is made from Premium Grade AISI 304/316 Stainless Steel (Non-Magnetic) with a reflection-free satin matte finish.
Surgeons use the instrument for exposure during tympanoplasty and ossiculoplasty in confined otologic spaces. Its compact, self-retaining configuration supports tissue counter-traction during delicate dissections. It is supplied non-sterile and is fully autoclavable. Individual protective packaging is provided.
Manufactured by Retractor Maker in Sialkot, Pakistan, this instrument is available for wholesale, OEM and distributor orders with worldwide shipping. Request a quote for your hospital, surgical practice or distribution business.
| Specification | Details |
|---|---|
| Intended Use | Specifically designed to retract the endaural incision margins and external auditory canal during otologic ear surgery. |
| Specialty | ENT (Ear, Nose & Throat) Surgery |
| Primary Material | Premium Grade AISI 304/316 Stainless Steel (Non-Magnetic) |
| Finish | Satin |
| Configuration | Compact self-retaining otologic retractor with mechanical lock |
| Overall Tool Length | 4 ¾ inches (12.06 cm) |
| Blade Geometry | Anatomically curved blades designed for safe meatal tissue displacement |
| Handle Layout | Ergonomically contoured handle frame designed to provide a firm, positive grip |
| Locking Mechanism | Precision mechanical locking system ensuring steady, continuous spread |
| Sterility | Supplied Non-Sterile (Fully Autoclavable) |
| Packaging | Individual Protective Packaging |
| Manufacturer | Retractor Maker |
| Product Condition | Brand New |
| Minimum Order Quantity (MOQ) | 1 Piece |
| Size | Price (USD) | SKU | Shipping |
|---|---|---|---|
| 4 1/2 in (11.4 cm) | $179 | RM-HER-475-1-1 | — |
| 4 3/4 in (12.06 cm) — Standard | $189 | RM-HER-475-1-2 | — |
Minimum order quantity:1 Piece.
Henner Endaural Retractor · PDF · English · 3 Pages
No reviews yet for this product. Be the first to share your experience.
The Henner Endaural Retractor combines solid one-piece construction, anatomically curved blades for safe meatal tissue displacement, and an ergonomically contoured handle frame for a firm, positive grip. Blade geometry spreads retraction force across a wider contact area, reducing tissue point pressure; handle ergonomics provide a secure, fatigue-resistant grip during long exposures. Its 4 ¾ inches (12.06 cm) overall length keeps the surgeon's hand clear of the operative field, while Premium Grade AISI 304/316 Stainless Steel (Non-Magnetic) (aisi 304/410) provides glare-free, corrosion-resistant service.
The Henner Endaural Retractor is used in ear surgery to hold open the endaural incision, providing an unobstructed microscopic view into the external auditory meatus and middle ear cavity. Its self-retaining configuration and mechanical lock maintain hands-free exposure during endaural procedures.
The Henner Endaural Retractor is indicated for tympanoplasty, stapedectomy, ossicular chain reconstruction, endaural mastoidectomy, and exploratory middle ear surgery. Its compact, self-retaining configuration supports tissue counter-traction during delicate dissections and provides exposure in confined otologic spaces.
The Henner Endaural Retractor is forged from high-tensile Premium Grade AISI 304/316 Stainless Steel (Non-Magnetic) with an anti-glare satin matte finish. This finish eliminates optical reflections under surgical operating microscopes during use in otologic ear surgery.
The entire Henner Endaural Retractor is 100% reusable and fully validated for pre-vacuum steam autoclave cycles (134°C / 273°F). The instrument is supplied non-sterile, and its mechanical locking joints should be cleaned and lubricated regularly.
The Henner Endaural Retractor is an integrated mechanical retractor supplied as a complete standalone unit rather than separate components and blades. Hospitals can order multiple units as open-stock inventory, and the minimum order quantity is 1 Piece.
Retractor Maker offers Henner Endaural Retractor customization upon request, including custom blade curvatures, altered handle frames, and laser marking for hospital asset tracking. The instrument is also available for wholesale, OEM and distributor orders with worldwide shipping.
In-stock Henner Endaural Retractor instruments take 5 business days to inspect and dispatch, followed by 7 business days for worldwide express delivery. Back-order units take 17 to 20 business days to manufacture and 9 business days for delivery.
Open the product page for the surgical retractor, blade or component you are interested in.
Choose whichever contact method is more convenient for you.
Discuss quantity, availability, shipping and payment details directly with our team.
Contact Retractor Maker for ordering and availability information.