
Caspar Cervical Retractor With Ratchet
From $289
SKU:RM-CSBR-1-1
$84.00USD
Cloward-Style Blade Retractor is used to retract the longus colli muscles and soft tissue during anterior cervical discectomy and fusion (ACDF). This handheld cloward retractor has a single-end blade with lipped or non-lipped tip options and a flat ergonomic handle with lateral serrations for tactile grip stability.
Cloward-Style Blade Retractor is a handheld instrument used in orthopedic spine surgery and neurosurgery to retract muscle, fascia, and visceral soft tissue during anterior cervical spine procedures. This cloward retractor exposes the anterior cervical spine and intervertebral disc spaces.
The single-end blade is available with or without a lip. The lipped tip helps prevent muscle creep over the blade margin; the non-lipped tip supports low-profile insertion in confined tissue planes. A flat ergonomic handle with lateral serrations provides tactile grip stability for manual retraction. It is made from Premium Grade AISI 304/316 Stainless Steel (Non-Magnetic) with a reflection-free satin matte finish.
Surgeons use the instrument for longus colli muscle retraction during anterior cervical discectomy and fusion (ACDF), multi-level cervical fusion, and corpectomy procedures. For operating room teams, it is supplied non-sterile, fully autoclavable, and individually packaged for protection.
Manufactured by Retractor Maker in Sialkot, Pakistan, it is available for wholesale, OEM and distributor orders with worldwide shipping. Request a quote for your preferred blade tip configuration.
| Specification | Details |
|---|---|
| Intended Use | Specifically designed to retract muscle, fascia, and visceral soft tissue during anterior cervical spine surgery. |
| Specialty | Orthopedic & Spine Surgery, Neurosurgery |
| Primary Material | Premium Grade AISI 304/316 Stainless Steel (Non-Magnetic) |
| Finish | Satin |
| Configuration | Handheld single-end cervical blade retractor |
| Overall Length | 19 cm (approx. 7.5 inches) |
| Selectable Blade Dimensions | 13 × 75 mm ($84.00), 18 × 75 mm ($89.00), 20 × 75 mm ($94.00), 23 × 75 mm ($99.00) |
| Selectable Tip Options | With Lip or Without Lip |
| Handle Profile | Flat ergonomic handle with lateral serrations for tactile grip stability |
| Sterility | Supplied Non-Sterile (Fully Autoclavable) |
| Packaging | Individual Protective Packaging |
| Manufacturer | Retractor Maker |
| Product Condition | Brand New |
| Minimum Order Quantity (MOQ) | 1 Piece |
| Size | Price (USD) | SKU | Shipping |
|---|---|---|---|
| 13 × 75 mm | $84.00 | RM-CSBR-1-1 | — |
| 18 × 75 mm | $89.00 | RM-CSBR-1-2 | — |
| 20 × 75 mm | $94.00 | RM-CSBR-1-3 | — |
| 23 × 75 mm | $99.00 | RM-CSBR-1-4 | — |
Minimum order quantity:1 Piece.
Cloward-Style Blade Retractor · PDF · English · 3 Pages
No reviews yet for this product. Be the first to share your experience.
The solid one-piece Cloward-Style Blade Retractor combines force-spreading blade geometry with ergonomic handling to reduce tissue point pressure. Blades: 13 × 75 mm ($84.00), 18 × 75 mm ($89.00), 20 × 75 mm ($94.00), 23 × 75 mm ($99.00); the flat ergonomic handle with lateral serrations for tactile grip stability provides secure, fatigue-resistant grip during long exposures. Length: 19 cm (approx. 7.5 inches), keeping hands clear; material: Premium Grade AISI 304/316 Stainless Steel (Non-Magnetic) (aisi 304/410), for glare-free, corrosion-resistant service.
The Cloward-Style Blade Retractor is used in anterior cervical spine surgery to retract the longus colli muscles and visceral structures away from the vertebral bodies, protecting the trachea and esophagus. This handheld instrument exposes the anterior cervical spine and intervertebral disc spaces.
The Cloward-Style Blade Retractor is indicated for Anterior Cervical Discectomy and Fusion (ACDF), anterior cervical corpectomy, cervical disc arthroplasty, and anterior trauma plating. The handheld instrument retracts muscle, fascia, and visceral soft tissue during anterior cervical spine procedures.
The Cloward-Style Blade Retractor is forged from high-tensile Premium Grade AISI 304/316 Stainless Steel (Non-Magnetic) with an anti-glare satin matte finish. The finish suppresses optical reflections under surgical operating lights and microscopes during anterior cervical spine procedures.
The entire Cloward-Style Blade Retractor is 100% reusable and fully validated for pre-vacuum steam autoclave cycles (134°C / 273°F). The instrument is supplied non-sterile and fully autoclavable, with individual protective packaging for protection during transit.
Each Cloward-Style Blade Retractor blade size is sold as a standalone unit because the instrument is a solid, one-piece handheld design. Hospitals can order multi-size sets to equip cervical spine trays, with blade tip options available With Lip or Without Lip.
Retractor Maker offers Cloward-Style Blade Retractor custom blade depths, modified lip geometries, and laser marking for hospital asset tracking upon request. The instrument is also available for wholesale, OEM and distributor orders, with worldwide shipping from Sialkot, Pakistan.
In-stock Cloward-Style Blade Retractor instruments take 5 business days to inspect and dispatch, followed by 7 business days for worldwide express delivery. Back-order units take 17 to 20 business days to manufacture and 9 business days for delivery.
Open the product page for the surgical retractor, blade or component you are interested in.
Choose whichever contact method is more convenient for you.
Discuss quantity, availability, shipping and payment details directly with our team.

From $289

From $109

From $699Free Shipping

From $94.00

From $109

$339
Contact Retractor Maker for ordering and availability information.